Name
Description
RUN indicator (green)
l
Steady on: The power module is working
properly.
l
Off: The power input or power module is faulty.
l
Blink once every 2 seconds (0.5 Hz): The power
module is in manual query state. This is a normal
state, and no action is required.
l
Blink four times every 1 second (4 Hz): The
power module is in program loading state. This is
a normal state, and no action is required. After the
program is loaded, the indicator blinks once every
2 seconds.
ALARM indicator (yellow)
l
Off: The power module does not have alarms.
l
Steady on: The power module has encountered a
fault, such as overvoltage, undervoltage, or
overcurrent.
l
Blink once every 2 seconds (0.5 Hz): The
communication of the power module has been
interrupted.
FAULT indicator (red)
l
Steady on: An unrecoverable fault occurs in the
power supply module, such as fan failure, no
output current, or short circuit of output current.
l
Off: The power module does not have any faults.
Buckle and ejector lever
-
The R4850G2 AC power module provides protection functions against:
l
Input overvoltage
l
Input undervoltage
l
Output overvoltage
l
Output current limiting
l
Output short circuit
l
Overtemperature
lists the technical specifications of the 4850G2 AC power module.
Table 1-29
Technical specifications of R4850G2 AC power module
Item
Description
Model
R4850G2
Dimensions (Height × Width ×
Depth)
40.8 mm x 105 mm x 281 mm
HUAWEI USG9500 Series
Hardware Guide
1 Hardware Overview
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
63