Panel
Figure 1-57
E8KE-X8-SFUC-200
RUN
ACT
OFL
SFUI-200-C
RUN
RU
N
ACT
AC
T
OFL
OF
L
SFUI-200-CS
FU
I-2
00
-C
Name
Description
OFL button
To remove a board, press and hold the button for six seconds
until the OFL indicator turns on.
OFL indicator (red)
Steady on: You can remove the board.
RUN indicator (green)
l
Blinks every 2 seconds (0.5 Hz): The system is working
properly.
l
Blinks twice each second (2 Hz): The system is in the alarm
state.
ACT (green)
l
Steady on: The SFU is working properly.
l
Off: The SFU is faulty.
Interface Attributes
The E8KE-X8-SFUC-200 does not have external interfaces.
Technical Specifications
shows the technical specifications of the E8KE-X8-SFUC-200.
Table 1-59
Technical specifications of the E8KE-X8-SFUC-200
Item
Specifications
Specifications
SFUI-200-C
Dimensions (width x
depth x height)
400 mm x 553.5 mm x 35 mm
Typical power
consumption
77 W
HUAWEI USG9500 Series
Hardware Guide
1 Hardware Overview
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
113