Figure A-34
Sliding the heat-shrink tubing onto the bare crimping terminal
Step 3
Fix the OT terminal (B) onto the exposed conductor, ensuring that the OT terminal is in
sufficient contact with the insulation layer of the power cable (C), as shown in
.
NOTICE
After the conductor is fed into the OT terminal, the protruding section of conductor (or L2 in
) must not exceed 2 mm.
Step 4
Crimp the joint parts of the bare crimping terminal and the conductor, as shown in
NOTE
The shapes of crimped parts may vary with the crimping dies.
Figure A-35
Crimping the joint parts of the bare crimping terminal and the conductor
Step 5
Slide the heat-shrink tubing (A) towards the connector until the tube covers the crimped part
and then heat the tube with a heat gun, as shown in
.
HUAWEI USG9500 Series
Hardware Guide
A Appendix
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
447