Figure A-33
Stripping a power cable (OT terminal)
NOTICE
l
When you strip a power cable, be careful not to damage the cable conductor.
l
If the bare crimping terminal is not provided by Huawei, the value of L1 is 1-2 mm greater
than L.
Table A-24
Mapping between the cross-sectional area of the conductor and the value of L1
Cross-
Sectional
Area of
Conductor
(mm
2
)
Value of L1 (mm)
Cross-Sectional
Area of Conductor
(mm
2
)
Value of L1 (mm)
1
7
10
11
1.5
7
16
13
2.5
7
25
14
4
8
35
16
6
9
50
16
NOTE
If you are proficient in assembling OT terminals and power cables, you can obtain the value of L1 by
simply comparing the part to be crimped with the power cable.
Step 2
Slide the heat-shrink tubing (A) onto the bare crimping terminal, as shown in
.
HUAWEI USG9500 Series
Hardware Guide
A Appendix
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
446