Cross-
Sectional
Area of
Conductor
(mm
2
)
Value of L1 (mm)
Cross-Sectional
Area of Conductor
(mm
2
)
Value of L1 (mm)
2.5
10
25
18
4
12
35
19
6
14
50
26
Step 2
Attach the cord end terminal (A) to the conductor, and ensure that the conductor is aligned
with the edge of the cord end terminal, as shown in
NOTICE
After the conductor is fed into the cord end terminal, ensure that the protruding length of
conductor does not exceed 1mm.
Figure A-44
Attaching the cord end terminal to the conductor
Step 3
Crimp the joint parts of the cord end terminal and the conductor, as shown in
Figure A-45
Crimping the cord end terminal and the conductor
Step 4
Check the maximum width of the tubular crimped terminal. Maximum widths are listed in
HUAWEI USG9500 Series
Hardware Guide
A Appendix
Issue 03 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
452