42
Chapter 2
Getting Started
Making a Measurement
If another function is activated, the frequency and amplitude can
still be identified by looking at the marker readout in the upper right
corner of the display.
Measurement Summary
1. Press the
Preset
key. Turn on the internal 50 MHz signal by pressing
System
,
50 MHz osc On Off
(On).
2. Set the center frequency by pressing the following keys:
Frequency
,
50 MHz
.
3. Set the span by pressing the following keys:
Span
,
20 MHz
.
4. The calibration signal is about
−
27 dBm (25 dBmV for Option 1DP),
below the top of the screen (almost three graticule divisions) using
these spectrum analyzer settings. If desired, adjust the reference
level: press
Amplitude
to activate the reference level, and use the
knob or step keys to change the reference level and bring the signal
to the top of the screen.
5. Determine the amplitude and frequency of the signal. You can either
press
Peak Search
or press
Marker
and move the marker to the signal
peak. Read the amplitude and frequency. The display should look
like the one in
Figure 2-5
. Frequency is displayed horizontally, and
amplitude (power) is displayed vertically.
Содержание ESA-L1500A
Страница 12: ...11 1 Preparing for Use and Printing ...
Страница 28: ...27 2 Getting Started ...
Страница 44: ...Chapter 2 43 Getting Started Making a Measurement Figure 2 5 Reading the Amplitude and Frequency ...
Страница 47: ...46 Chapter2 Getting Started Analyzer Battery Information ...
Страница 48: ...47 3 Troubleshooting ...
Страница 54: ...Chapter 3 53 Troubleshooting How to Return Your Analyzer for Service Figure 3 1 ...
Страница 117: ...116 Chapter4 Front Panel Key Reference Trig ...
Страница 118: ...117 5 Menu Maps ...
Страница 119: ...118 Chapter5 Menu Maps ...
Страница 120: ...Chapter 5 119 Menu Maps ...
Страница 121: ...120 Chapter5 Menu Maps ...
Страница 122: ...Chapter 5 121 Menu Maps ...
Страница 124: ...Chapter 5 123 Menu Maps ...
Страница 125: ...124 Chapter5 Menu Maps ...
Страница 127: ...126 Chapter5 Menu Maps a Frequency is replaced with Time when the X Axis Units Freq Time selection is Time ...
Страница 128: ...Chapter 5 127 Menu Maps ...
Страница 129: ...128 Chapter5 Menu Maps ...
Страница 130: ...Chapter 5 129 Menu Maps ...
Страница 131: ...130 Chapter5 Menu Maps ...
Страница 135: ...134 Chapter5 Menu Maps ...
Страница 136: ...135 6 Options and Accessories ...
Страница 145: ...144 Chapter6 Options and Accessories Accessories ...
Страница 146: ...145 7 Specifications ...
Страница 179: ...178 Chapter7 Specifications Regulatory Information ...
Страница 180: ...179 8 Required Equipment ...
Страница 187: ...186 Chapter8 Required Equipment Test Equipment ...
Страница 308: ...307 10 Performance Verification Test Record ...
Страница 321: ...320 Chapter10 Performance Verification Test Record HP ESA L1500A Performance Verification Test Record ...