Fabric OS 5.2.x administrator guide 237
6.
Log in to the switch and issue the
nsAllShow
or the
nsCamShow
command.
All of the devices from both LSANs should appear in the output. If the devices do not appear in the
output, issue the
cfgShow
command to verify your zone configuration. Use the
cfgactvshow
command to display the zone configuration currently in effect. The following example illustrates the use
of
cfgactvshow
.
7.
Log into the FC router and run the
lsanZoneShow
command to verify FIDs and devices to be shared
among LSANs.
edgeswitch:admin_06>
nsallshow
{
010e00 020000 03f001 04f002
4 Nx_Ports in the Fabric }
edgeswitch:admin_06>
nscamshow
nscam show for remote switches:
Switch entry for 1
state rev owner
known v520 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 010e00; 3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 03f001; 2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2 DV5-5.10A10 "
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 04f002; 3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
Fabric Port Name: 50:06:06:91:23:45:6a:13
Permanent Port Name: 10:00:00:00:00:03:00:00
Port Index: na
Share Area: No
Device Shared in Other AD: No
switch:admin> cfgactvshow
Effective configuration:
cfg:
test
zone:
lsan_san
10:00:00:00:00:03:00:00
10:00:00:00:00:01:00:00
zone:
lsan_test
50:06:01:60:38:e0:0b:a4
10:00:00:00:c9:44:54:04
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......