Fabric OS 5.2.x administrator guide 173
Message
The command failed because IPSec is enabled. Please use the
portcfg fciptunnel
command to disable
it before proceeding.
Probable Cause and Recommended Action
The
firmwareDownload
operation was attempting to downgrade a system to Fabric OS v5.1.0 or lower
and the IPsec feature is enabled. The IPsec feature is not supported on firmware v5.1.0 or lower, so the
firmwareDownload operation failed.
Disable IPSec using the
portCfg fcipTunnel
command. Retry the firmware download operation.
Message
The command failed because Tape Pipelining is enabled. Please use the
portcfg fciptunnel
command
to disable it before proceeding.
Probable Cause and Recommended Action
The firmware download operation was attempting to downgrade a system to Fabric OS v5.1.0 or lower
and the tape pipelining feature is enabled. Tape pipelining is not supported on firmware v5.1.0 or lower,
so the firmware download operation failed.
Disable tape pipelining using the
portCfg fcipTunnel
command. Retry the firmware download
operation.
Message
The command failed due to the presence of trunking on an EX-Port. Please run
switchCfgTrunk
or
portCfgTrunkPort
CLI
CLI commands to disable the EX-Port trunking before proceeding.
Probable Cause and Recommended Action
The firmware download operation was attempting to downgrade a system to Fabric OS v5.1.0 or lower
and trunking is enabled on an EX_Port. EX_Port trunking is not supported on firmware v5.1.0 or lower, so
the firmware download operation failed.
Disable the trunking on the EX_Port using the
portCfgTrunkPort
command, or disable trunking on all
ports on the switch using the
switchCfgTrunk
command. Retry the firmware download operation.
NOTE:
The messages might be displayed a number of times during the checking and summary phases of
the firmware download operation. You need pay attention only to messages displayed
during the
summary phase
.
Message
The command failed due to strict fabric wide policy is configured. Please use the
fddcfg -fabwideset
command to disable it before proceeding.
Probable Cause and Recommended Action
The firmware download operation was attempting to downgrade a system to Fabric OS v5.1.0 or lower
and a strict fabric-wide policy is enabled. The fabric-wide policy can be set to “strict”
only
when all
switches in the fabric are running firmware v5.2.x or higher, so the firmware download operation failed.
Either reset or disable the fabric-wide policy setting as follows:
•
Reset the fabric-wide policy as “tolerant” using the
fddCfg --fabWideSet "policyname"
command. The “tolerant” setting allows switches with different firmware versions within the fabric,
however all fabric-wide consistency mechanisms will be applied only to switches running firmware
v5.2.x or higher.
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......