Fabric OS 5.2.x administrator guide 299
Correcting marginal links
A marginal link involves the connection between the switch and the edge device. Isolating the exact cause
of a marginal link involves analyzing and testing many of the components that make up the link (including
the switch port, switch SFP, cable, the edge device, and the edge device SFP).
To troubleshoot a marginal link:
1.
Enter the
portErrShow
command.
2.
Establish if there are a relatively high number of errors (such as CRC errors or ENC_OUT errors), or if
there are a steadily increasing number of errors to confirm a marginal link.
3.
If you suspect a marginal link, isolate the areas by moving the suspected marginal port cable to a
different port on the switch. Re-seating of SFPs may also cure marginal port problems.
If the problem stop, the switch port or the SFP is marginal (proceed to
step 4
)
If the problem does
not
stop, refer to
step 7
.
4.
Replace the SFP on the marginal port.
switch:admin>
porterrshow
frames enc crc too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
sig=====================================================================
0: 22 24 0 0 0 0 0 1.5m 0 7 3 0 0 0
1: 22 24 0 0 0 0 0 1.2m 0 7 3 0 0 0
2: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4: 149m 99m 0 0 0 0 0 448 0 7 6 0 0 0
5: 149m 99m 0 0 0 0 0 395 0 7 6 0 0 0
6: 147m 99m 0 0 0 0 0 706 0 7 6 0 0 0
7: 150m 99m 0 0 0 0 0 160 0 7 5 0 0 0
8: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
12: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
13: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
15: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
32: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
33: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
34: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
35: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
36: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
37: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
38: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
39: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
40: 99m 146m 0 0 0 0 0 666 0 6 796 7 0 0
41: 99m 149m 0 0 0 0 0 15k 0 2 303 4 0 0
42: 99m 152m 0 0 0 0 0 665 0 2 221 5 0 0
43: 99m 147m 0 0 0 0 0 16k 0 2 144 4 0 0
44: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
45: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
46: 0 0 0 0 0 0 0 0 0 0 0 2 0 0
47: 0 0 0 0 0 0 0 0 0 0 0 0 0 0
switch:admin>
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......