Fabric OS 5.2.x administrator guide 211
To view a DH-CHAP secret word database
1.
Log in as
admin
to the 400 MP Router or 4/256 SAN Director with a B-Series MP Router blade.
2.
At the telnet prompt, enter the
secAuthSecret
command as shown:
For details about the
setAuthSecret
command, see the Secure Fabric OS Administrator’s Guide.
Configuring an interfabric link
Before configuring an IFL, be aware that you cannot configure both IFLs (EX_Ports, VEX_Ports) and ISLs
(E_Ports) from a single 400 MP Router or B-Series MP Router blade to the same edge fabric.
Configuring an interfabric link involves disabling ports and cabling them to other fabrics, configuring those
ports for their intended use, and then enabling the ports.
When it is in strict mode, ACL cannot support Fibre Channel routing in the fabric. Before connecting an
edge fabric to an FC router and before setting up the FC router in the BB, verify that the Fabric Wide
Consistency Policy is not in ‘strict’ mode by issuing the
fddCfg --showall
command.
If the Fabric Wide Consistency Policy has the ‘S’ letter in it in the edge fabric or the BB fabric, do not
connect the edge fabric or the BB to the FC router.
NOTE:
To ensure that fabrics remain isolated, disable the port prior to inserting the cable. If you are
configuring an EX_Port, disable the port prior to making the connection.
To configure an IFL for both edge and backbone connections
1.
On the 400 MP Router or B-Series MP Router blade, disable the port that you are configuring an
EX_Port (the one connected to the switch) by issuing the
portDisable
command.
You can verify that port 7 has been disabled by issuing the
portShow
command for the port.
2.
Configure each port that connects to an edge fabric as an EX_Port or VEX_Port. Note the following:
•
portCfgVEXPort
works only on the GbE ports.
•
portCfgEXPort
(only on the FC ports on the 400 MP Router or 4/256 SAN Director with a
B-Series MP Router blade) commands work only on ports that are capable of FC-FC routing.
Use the
portCfgEXPort
or
portCfgVEXPort
command to:
• Enable or disable EX_Port or VEX_Port mode.
• Set the fabric ID (avoid using fabric ID 1, which is the default for backbone connections).
switch:admin_06>
secauthsecret --show
WWN DId
Name
------------------------------------------------------------
10:00:00:60:69:80:05:14 1
switch
switch:admin_06>
portdisable 7/10
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......