274 Working with diagnostic features
To display temperature status
1.
Connect to the switch and log in as admin.
2.
At the command line, enter the
tempShow
command:
Information displays for each temperature sensor in the switch.
The possible temperature status values are:
OK—Temperature is within acceptable range.
FAIL—Temperature is outside of acceptable range. Damage might occur.
Viewing the system message log
The system message log feature enables messages to be saved across power cycles and reboots.
The HP StorageWorks Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director Director models
maintain an independent system message log for each of the two CP blades. For these models, you should
configure syslogd to support chronological system message logs. For details, see ”
Configuring for syslogd
”
on page 276.
For details on error messages, refer to the
Fabric OS System Error Message Reference Manual
.
To display the system message log, with no page breaks
1.
Connect to the switch and log in as
admin
.
2.
Enter the
errDump
command at the command line.
To display the system message log one at a time
1.
Connect to the switch and log in as
admin
.
2.
Enter the
errShow
command at the command line.
To clear the system message log
1.
Connect to the switch and log in as
admin
.
2.
Enter the
errClear
command at the command line.
All switch and chassis events are removed.
switch:admin>
tempshow
Index Status Centigrade Fahrenheit
----------------------------------------------------
1 OK 21 70
2 OK 22 72
3 OK 29 84
4 OK 24 75
5 OK 25 77
switch:admin>
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......