Fabric OS 5.2.x administrator guide 163
5. Update firmware on standby CP
a.
Start a telnet session on the standby CP (which is the old active CP).
b.
Enter the
firmwareDownload -s
command and respond to the prompts as follows:
At this point the firmware should download to the standby CP only and reboot it. The telnet session
will be disconnected.
c.
Wait one minute for the standby CP to reboot, and then start a telnet session and log in as
admin
.
d.
Enter the
firmwareShow
command to confirm that
both
primary partitions now have the test drive
firmware in place.
You are now ready to evaluate the new version of the firmware.
NOTE:
Stop!
If you wish to
restore
the firmware, stop here
and skip ahead to step 8; otherwise, continue
to step 6 to commit the firmware on both CPs, which completes the firmware download.
6. Perform commit on standby CP
In the telnet session on the standby CP, enter the
firmwareCommit
command to update the
secondary partition with new firmware. Note that it takes several minutes to complete the commit
operation.
7. Perform commit on active CP
a.
From the telnet session on the active CP, enter the
firmwareShow
command and confirm that only
the active CP secondary partition contains the old firmware.
b.
Enter the
firmwareCommit
command to update the secondary partition with new firmware. Note
that it takes several minutes to complete the commit operation.
c.
Enter the
firmwareShow
command to confirm both partitions on both CPs contain the new
firmware.
d.
Enter the
haShow
command to confirm that the HA state is in sync.
NOTE:
Stop!
If you have completed step 7, then you have committed the firmware on both CPs and you
have completed the firmware download procedure. Steps 8-10 describe how to restore the original
firmware, and should be performed after step 5.
8. Restore the firmware on the standby CP
In the telnet session for the standby CP, enter the
firmwareRestore
command. The standby CP will
reboot and the telnet session will end. Both partitions will be made equal after several minutes.
9. Perform haFailover on active CP
a.
In the telnet session for the active CP, enter the
haShow
command to verify that HA synchronization
is complete. It will take a minute or two for the standby CP to reboot and synchronize with the active
CP.
b.
Enter the
haFailover
command. The active CP will reboot and the telnet session will end. Your
switch is now running the original firmware.
switch:admin>
firmwaredownload -s
Server Name or IP Address:
10.1.2.3
FTP User Name:
JaneDoe
File Name:
/pub/v5.2.x
FTP Password:
Do Auto-Commit after Reboot [Y]:
n
Reboot system after download [N]:
y
Firmware is being downloaded to the switch. This step may take up to 30
minutes.
Checking system settings for firmwaredownload...
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......