Fabric OS 5.2.x administrator guide 285
To check the Name Server (NS)
1.
Enter the
nsShow
command on the switch to which the device is attached:
2.
Look for the device in the NS list, which lists the nodes connected to that switch, allowing you to
determine if a particular node is accessible on the network.
• If the device is
not
present in the NS, the problem is between the storage device and the switch.
There might be a time-out communication problem between edge devices and the Name Server, or
there might be a login issue. First check the edge device documentation to determine if there is a
time-out setting or parameter that can be reconfigured. You should also check the port log for NS
registration information and FCP probing failures (using the
fcpProbeShow
command). If these
queries do not help solve the problem, contact the support organization for the product that appears
to be inaccessible.
• If the device
is
listed in the NS, the problem is between the storage device and the host. There might
be a zoning mismatch or a host/storage issue. Proceed to
”
To check for zoning problems
” on
page 286.
3.
Enter the
portLoginShow
command to check the port login status.
4.
Enter the
fcpProbeShow
command to display the FCP probing information for the devices attached to
the specified F_Port or L_Port. This information includes the number of successful logins and SCSI
INQUIRY commands sent over this port and a list of the attached devices.
5.
Check the port log to determine whether or not the device sent the FLOGI frame to the switch, and the
switch probed the device.
The Local Name Server has 9 entries {
Type Pid COS PortName NodeName TTL(sec)
*N 021a00; 2,3;20:00:00:e0:69:f0:07:c6;10:00:00:e0:69:f0:07:c6; 895
Fabric Port Name: 20:0a:00:60:69:10:8d:fd
NL 051edc; 3;21:00:00:20:37:d9:77:96;20:00:00:20:37:d9:77:96; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051ee0; 3;21:00:00:20:37:d9:73:0f;20:00:00:20:37:d9:73:0f; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051ee1; 3;21:00:00:20:37:d9:76:b3;20:00:00:20:37:d9:76:b3; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051ee2; 3;21:00:00:20:37:d9:77:5a;20:00:00:20:37:d9:77:5a; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051ee4; 3;21:00:00:20:37:d9:74:d7;20:00:00:20:37:d9:74:d7; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051ee8; 3;21:00:00:20:37:d9:6f:eb;20:00:00:20:37:d9:6f:eb; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL 051eef; 3;21:00:00:20:37:d9:77:45;20:00:00:20:37:d9:77:45; na
FC4s: FCP [SEAGATE ST318304FC 0005]
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
N 051f00; 2,3;50:06:04:82:bc:01:9a:0c;50:06:04:82:bc:01:9a:0c; na
FC4s: FCP [EMC SYMMETRIX 5267]
Fabric Port Name: 20:0f:00:60:69:10:9b:5b
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......