Performing basic configuration tasks
ISL mode L0 is available on all Fabric OS releases. When you upgrade from Fabric OS 4.0.0 to Fabric
4.1.0 or later, all extended ISL ports are set automatically to L0 mode.
For information on extended ISL modes, which enable longer distance interswitch links, refer to
”
Administering Extended Fabrics
” on page 325.
Linking through a gateway
A gateway merges SANs into a single fabric by establishing point-to-point E_Port connectivity between two
Fibre Channel switches that are separated by a network with a protocol such as IP or SONET.
Except for link initialization, gateways are transparent to switches; the gateway simply provides E_Port
connectivity from one switch to another.
By default, switch ports initialize links using the Exchange Link Parameters (ELP) mode 1. However,
gateways expect initialization with ELP mode 2, also referred to as ISL R_RDY mode. Therefore, to enable
two switches to link through a gateway, the ports on both switches must be set for ELP mode 2.
Any number of E_Ports in a fabric can be configured for gateway links, provided the following rules
are followed:
•
All switches in the fabric must be upgraded to Fabric OS 3.1.0 (or later) or 4.1.0 (or later).
•
To prevent fabric segmentation, make sure that all switches in the fabric are using the core PID format,
as described in ”
How to configure a link through a gateway
” described next.
•
When determining switch count maximums, include the switches connected to both sides of
the gateway.
•
Extended links (those created using the Extended Fabrics licensed feature) and the security features in
Secure Fabric OS are not supported through gateway links.
How to configure a link through a gateway
1.
If you are not sure that the PID format is consistent across the entire fabric, enter the
configShow
command on all switches to check the PID setting. If necessary, change the PID format on any
nonconforming switches, as described in ”
Configuring the PID format
” on page 381.
2.
Connect to the switch on one end of the gateway and log in as
admin
.
3.
Enter the
portCfgIslMode
command:
In the following example, slot 2, port 3 is enabled for a gateway link:
4.
Repeat the steps for any additional ports that will be connected to the gateway.
5.
Repeat the procedure on the switch at the other end of the gateway.
4/16 SAN Switch and 4/8 SAN Switch,
SAN Switch 2/8V, SAN Switch 2/16V,
SAN Switch 2/32, SAN Switch 4/32,
4/64 SAN Switch, and 400 MP Router
portCfgIslMode
port
mode
Specify a
port
number. Valid values for port
number vary depending on the switch type. The
mode operand is required: specify 1 to enable
ISL R_RDY mode (gateway link) or specify 0 to
disable it.
SAN Director 2/128 and 4/256 SAN
Director:
portCfgIslMode
slot
/
port
,
mode
Specify a
slot
/
port
number pair. Valid values for
slot and port number vary depending on the
switch type. The mode operand is required:
specify 1 to enable ISL R_RDY mode (gateway
link) or specify 0 to disable it.
switch:admin>
portcfgislmode 2/3, 1
Committing configuration...done.
ISL R_RDY Mode is enabled for port 3. Please make sure the PID
formats are consistent across the entire fabric.
switch:admin>
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......