154 Installing and maintaining firmware
8.
Respond to the prompts as follows:
After the firmware is downloaded, the switch performs an HA reboot and starts the firmware commit.
9.
After the HA reboot, connect to the switch and log in again as
admin
.
10.
If you want snapshots of the upgrade progress, using a separate telnet session, enter the
firmwareDownloadStatus
command to monitor the firmware download.
11.
After the firmware commit is completed, enter the
firmwareShow
command to display the firmware
level of both partitions. It takes several minutes to complete the commit operation.
The firmware is downloaded to one CP blade at a time, beginning with the standby CP blade. During
the process, the active CP blade is failed over. After the firmware is downloaded, a firmware commit
starts on both CP blades. The entire firmware download and commit process takes approximately 35
minutes.
If there is an AP blade present
: At the point of the failover an
autoleveling
process is activated.
autoleveling is triggered when the active CP detects a blade that contains a different version of the
firmware, regardless of which version is older. Autoleveling downloads firmware to the AP blade,
swaps partitions, reboots the blade, and copies the new firmware from the primary partition to the
secondary partition. If you have multiple AP blades, they are updated simultaneously; however, the
downloads can occur at different rates.
Server Name
or IP Address
Enter the name or IP address of the FTP server where the firmware file is
stored; for example, 192.1.2.3. You can enter a server name if DNS is
enabled.
User name
Enter the user name of your account on the server; for example, “JohnDoe”.
File name
Fabric OS 5.2.x or higher
: Specify the full path name of the firmware
directory, for example,
/pub/v5.2.x
.
Fabric OS 5.1.x or lower
: Specify the full path name of the firmware
directory, appended by
release.plist
; for example,
/pub/v5.1.x/release.plist
.
Note
: For v4.x and v5.x switches only, do not attempt to locate the
release.plist
file in the top level directory; there is a
release.plist
file for
each platform, and the correct one is automatically selected.
Password
Enter your account password for the server. Note that this is a required
field even if you are logged in as an anonymous user; in such cases, the
value may be ignored by the FTP service.
switch:admin>
firmwaredownload
Server Name or IP Address:
10.1.2.3
FTP User Name:
JaneDoe
File Name:
/pub/v5.2.x
FTP Password:
xxxx
Verifying the input parameters ...
Checking system settings for firmwaredownload...
You can run firmwaredownloadstatus to get the status
of this command.
This command will cause a warm/non-disruptive boot on the switch,
but will require that existing telnet, secure telnet or SSH sessions
be restarted.
Do you want to continue [Y]
y
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......