336 Administering ISL Trunking
Monitoring traffic
To implement ISL Trunking effectively, you must monitor fabric traffic to identify congested paths or to
identify frequently dropped links. While monitoring changes in traffic patterns, you can adjust the fabric
design accordingly, such as by adding, removing, or reconfiguring ISLs and trunking groups in
problem areas.
There are three methods of monitoring fabric traffic:
•
Advanced Performance Monitoring
monitors traffic flow and allows you to view the impact of different
fabric configurations on performance. Refer to ”
Administering Advanced Performance Monitoring
(APM)
” on page 327 for additional information.
•
Fabric Watch
allows you to monitor traffic flow through specified ports on the switch and send alerts
when the traffic exceeds or drops below configurable thresholds. Refer to the
Fabric Watch
Administrator’s Guide
for additional information.
•
Use the
portPerfShow
command as described in the following procedure to record traffic volume for
each port in your fabric over time.
To use the
portPerfShow
command
1.
Connect to the switch and log in as admin.
2.
Enter the following command:
where
interval
is the number of seconds between each data-gathering sample (the default is one
sample every second).
3.
Record the traffic flow for each port participating in an ISL.
4.
Repeat
step 1
through
step 3
for each switch in the fabric until all ISL traffic flow is captured.
In a large fabric, it might be necessary to only identify and capture the key ISLs. However, you might
want to continue this process throughout the day (or an entire work cycle), to capture varying traffic
patterns under different conditions.
The following example shows a switch without trunking, and indicates that ports 0 through 2 are
underutilized and ports 4 and 5 are congested:
The following example shows traffic flowing through a trunking group (ports 5, 6, and 7). After port 6
fails, traffic is redistributed over the remaining two links in the group, ports 5 and 7:
portperfshow
[interval]
switch:admin>
portperfshow
0
1
2
3
4
5
6
7
Total
--------------------------------------------------------------------
0
0
0
145m
204m
202m
0
168m 719
0
0
0
145m
206m
208m
0
186m 745
switch:admin>
switch:admin>
portperfshow
0
1
2
3
4
5
6
7
Total
--------------------------------------------------------------------
0
0
0
0
0
145m
144m
145m
434
0
0
0
0
0
144m
143m
144m 431
0
0
0
0
0
162m
0
162m
324
0
0
0
0
0
186m
0
186m 372
0
0
0
0
0
193m
0
192m 385
0
0
0
0
0
202m
0
202m 404
0
0
0
0
0
209m
0
209m 418
switch:admin>
Содержание AE370A - Brocade 4Gb SAN Switch 4/12
Страница 1: ...HP StorageWorks Fabric OS 5 2 x administrator guide Part number 5697 0014 Fifth edition May 2009 ...
Страница 18: ...18 ...
Страница 82: ...82 Managing user accounts ...
Страница 102: ...102 Configuring standard security features ...
Страница 126: ...126 Maintaining configurations ...
Страница 198: ...198 Routing traffic ...
Страница 238: ...238 Using the FC FC routing service ...
Страница 260: ...260 Administering FICON fabrics ...
Страница 280: ...280 Working with diagnostic features ...
Страница 332: ...332 Administering Extended Fabrics ...
Страница 414: ...398 Configuring the PID format ...
Страница 420: ...404 Configuring interoperability mode ...
Страница 426: ...410 Understanding legacy password behaviour ...
Страница 442: ...426 ...
Страница 444: ......
Страница 447: ......