6-36
6.2.22 Inside Temperature Sensor Fault
(*1): When you replace thermistor, refer to “4.12.5 Replacing thermistor”
(*2): When you replace EZJ133 board, refer to
[Replacement procedures of EZJ133 board] in “3.3.1 EZJ133
board (MPU board)”.
[Caution]
Be sure to check that there is no wrong connection of harnesses by referring to
[Connector numbers and
Identifying method of harnesses] in “3.3.20 Electrical Connection Diagram”.
Viscometer Ink
Temperature Sensor
Fault
Replace the thermistor of Viscometer*1.
Replace the EZJ133 board*2.
Resume the
operation
.
Does the fault recur?
Yes
No
Does the fault recur?
Yes
No
Disconnect and reconnect the following
connectors.
▪ EZJ133: CN13
▪ EZJ138: CN1, CN4
▪ Thermistor relay harness connector
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Страница 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Страница 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...