3-40
3.3.14 EZJ129 board (Software option terminal board)
[Function]
-
Input / output terminal board when software option is used.
[Note for the board replacement]
- Before replacing the board, be sure to turn the main power switch OFF.
-
After replacing the board, be sure to connect the connectors in place.
- Before replacing the board, be sure that the electric power is NOT supplied to the wires
connecting to TB3.
- Perform the settings of SW4 to 8.
[EZJ129 external view]
[Replacement procedures of EZJ129 board]
(1) Turn main power switch OFF and open the top cover.
(2) Remove the connectors (CN8, CN9, CN4) and wires connected to TB3.
(3) Remove two fixing screws, and then replace EZJ129 with a new one.
(4) Reassemble the removed parts in reverse order of the procedures above.
(5) Perform the settings of SW4 to SW8.
- Inside the top cover (upper part of cabinet)
Fixing screws (2pcs)
EZJ129 board
EZJ119A board
(Option)
EZJ127A board
TB3 : External signal terminal
Fixing screw
CN4:
External communication (RS-232C)
D-SUB 9-pin connector
CN8:
Connector for EZJ130
Fixing screw
CN9:
Connector for EZJ130
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Страница 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Страница 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...
Страница 355: ...7 4 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65μm Nozzle 2 side Nozzle 1 side ...