4-44
4.9.2 Circulation Filter and Makeup Filter in Nozzle 2 path Replacement Procedure
1
Perform the procedures described in “4.1.2 Access to the parts on the front side of
equipment” and pull the Reservoir unit forward.
Replacement of makeup filter 2
2
Rotate the nut of the makeup filter and pull it out.
3 Remove the used O-ring and its filter and mount the new ones.
4 Reset the circulation filter time and/or the makeup filter time
to "0" on the “Parts usage
t
ime management” screen.(Second page of the circulation control screen)
O-ring
Filter
Nut
If the ink was accidentally
spilled, quickly wipe it off
with wiping paper, etc. In
addition, do not close the
maintenance cover until you
confirm that the wiped part
completely get dry.
CAUTION
Maleup Filter