4-55
4.12.3 Viscometer assembly procedure
1 Replace the cylinder, and then insert the plunger. Handle the plunger with tweezers
making sure that no dust adheres to the surface of plunger.
2 Set the collar to cylinder, paying extra attention to its orientation (with the convex up).
3 Make sure that the O-ring is set in the viscometer cover, and then assemble the cover into
the viscometer case.
4 Attach the three viscometer setscrews and tighten them. (Tighten the screws with
reasonable force using screwdriver. Tightening the screws excessively will break the
threads.)
4.12.4 Viscometer attaching procedure
1 Set the O-ring on the viscometer OUT side, and use the setscrews (2 pieces) to attach the
viscometer to the circulation unit.
2 Plug in the connectors.
3 Connect the viscometer IN-side tube (mark G).
[Caution] After reassembly, it may be necessary to replace the ink and/or calibrate the
viscometer.
When disassembling and washing during installation:
Calibrate the viscometer. Ink replacement is NOT required.
When replacing the viscometer during installation:
Calibrate the viscometer. Ink replacement is NOT required.
When replacing the viscometer in cases other than installation:
First replace the ink, then calibrate the viscometer.
O-ring
Viscometer case
Viscometer IN joint
Viscometer cover
Plunger
Cylinder
Coil
Collar
O-ring
O-ring
Thermistor
Fixing
plate
Viscometer-IN
Viscometer-Out
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Страница 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Страница 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...
Страница 355: ...7 4 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65μm Nozzle 2 side Nozzle 1 side ...