4-25
4.8 Pump part replacement
4.8.1 Pump Unit Replacement Procedure
1
Perform “Ink drainage” to “Pressure relief”.
2 Turn off the power supply.
3 Perform
“4.1.3 Access to the parts on the rear side of the equipment”, “(1) Access
method from the front
” and open the unit door.
[Caution] Be careful not to catch the tubes.
4 Remove the wire harness from the clamps (6 positions).
5 Disengage the connectors of the electrical parts (6 positions) (pressure sensor,
viscometer (3 positions), level sensor and float sensor).
5 positions
1 position
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Страница 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Страница 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...
Страница 355: ...7 4 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65μm Nozzle 2 side Nozzle 1 side ...