4-36
4 Remove Motor connection connector and Tube (Mark: AA) in Recovery pump
unit.
5 Holding the drive unit by hand, remove the fixing screw (1 piece) of Recovery pump unit
.
6 Pull the Recovery pump unit forward.
Motor connection connector
Recovery pump unit
Fixing screw
Fixing screw
Mark: AA
If the ink was accidentally
spilled, quickly wipe it off
with wiping paper, etc. In
addition, do not close the
maintenance cover until you
confirm that the wiped part
completely get dry.
CAUTION
Recovery pump unit
Pull forward