![Hitachi UX Twin Nozzle Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/hitachi/ux-twin-nozzle/ux-twin-nozzle_service-manual_143808154.webp)
4-20
4.6.2 Pressure Sensor (Nozzle 2) Replacement Procedure
1 Perform
“Nozzle Backwash 2”. (Till stopped automatically without sucking
the makeup into the gutter)
2 Turn off the power supply.
3 Perform
“4.1.3 Access to the parts on the rear side of the equipment”.
(The reason is that the connector is located on the rear side of the equipment.)
4 Remove the connector of the pressure sensor.
5 Remove the screws that fix the
Solenoid valve base
.
Connector for pressure sensor
Unit door
Pressure sensor
[Caution]
When unplugging the connector, be
sure to pull out straight. Do not twist
off or it may break the connector.
Fixing screws for solenoid valve base