(2) Fault locating method for the control system/circulation system
(a) When the pump motor and all the solenoid valves are not operated, the multi-power supply
(24 V system) is abnormal.
(b) If the electrical parts (pump motor, solenoid valves, and pressure sensor) are not operated, i,e.,
any case other than above, make the following checks first. When the criterion is satisfied, the
power supply, EZJ126 board, wiring, or connector is abnormal.
Part
Check method
Criterion
Pump motor
(1) Operate the pump on
the
“Solenoid
Valve/Pump Test
”
screen.
(2) Measure the
voltage at pin
No.5 (wire: red)
20 V DC or more
Solenoid valve
(1) Exchange the
solenoid valve and/or
the connector with
another normal
solenoid valve and/or
connector.
(2) Set the solenoid
value to
“Open” on
the
“Solenoid
Valve/Pump Test
”
screen and check the
sound.
An operation sound shall
be produced.
Pressure sensor
Measure the voltage at
pin No.1
(wire: yellow)
DC12V
±
10%
Measure the voltage at
pin No.3 (wire: blue)
when the ink is jetting.
Pressure
[MPa]
Output
voltage [V]
0.1
1.5 to 1.6
0.2
2.1 to 2.2
0.3
2.7 to 2.8
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...
Страница 352: ...7 1 7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram ...
Страница 354: ...7 3 7 3 Electrical Connection Diagram Electrical Connection Diagram ...
Страница 355: ...7 4 7 4 Dimensions around charge electrode and deflection electrode Nozzle diameter 65μm Nozzle 2 side Nozzle 1 side ...