![Hitachi UX Twin Nozzle Скачать руководство пользователя страница 101](http://html.mh-extra.com/html/hitachi/ux-twin-nozzle/ux-twin-nozzle_service-manual_143808101.webp)
3-25
3.3.7 EZJ127 board (I/O board)
[Function]
- Connect I/F signal with the conveyer.
Output signal: Ready, Fault, Warning, Print-in-progress/Print-complete, On-line,
Universal output 1, Universal output 2
Input signal:
Print target detector, Print stop, Reciprocative printing,
Encoder (for product speed matching), Deflection voltage ON/OFF,
Run, Reset, Stop
- External communication: RS-232C connection
[Input / Output signals of terminal block (TB1) and remarks]
Pin
No.
Name of signal
Input / Output
Remarks
NPN Interface
PNP Interface
NPN
PNP
1
Power supply for Print target detector
Output
- DC24V,100mA max.
(*1)
- Power supply and NPN / PNP can be
selected by SW1
2
Print target detector
Input
3
Ground for Print target detector
-
4
Print stop
Input
- NPN / PNP can be selected by SW2
5
Signal ground
-
6
Power supply for encoder
Output
- DC24V,100mA max.
(*1)
- Totem pole / Open collector (NPN) can be
selected by SW1
- Power supply can be selected by SW1
7
Encoder signal (Totem pole)
Input
8
Encoder signal (Open collector NPN)
Input
9
Ground for Encoder
-
10
Ready
-
Output
-
- Open collector (NPN) only.
11
Signal ground
-
-
-
12
Fault
-
Output
-
13
Warning
-
Output
-
14
Deflection voltage ON/OFF signal
Input
- NPN / PNP can be selected by SW2.
15
Reciprocative print signal
Input
16
Run signal
Input
17
Reset signal
Input-
18
Stop signal
Input-
19
Print-in-progress / Print-complete
Output
- Print-in-progress/ Print-complete can be
selected with screen operation.
- NPN / PNP can be selected by SW2
20
Online output
Output
21
Universal output 1
Output
22
Universal output 2
Output
23
Signal ground
-
(Note 1): Available supply current for print target detector and encoder is up to 100mA in total.
With respect to the wiring,
refer to Technical manual
“4
Electnic signal connection
”
- Wrong wiring will cause the board breakdown.
Before wiring, be sure to confirm the
terminal signal.
- Be sure to turn OFF the main power switch before you start the external wiring.
!
Caution wiring for external
Содержание UX Twin Nozzle
Страница 1: ...Service Manual HITACHI Printer UX Twin Nozzle Model Revision February 2017 Version A ...
Страница 106: ...3 30 Circuit diagram of EZJ127A board ...
Страница 123: ...3 47 Circuit diagram of EZJ129 board ...
Страница 131: ...3 55 3 3 20 Electrical Connection Diagram ...
Страница 151: ...4 17 7 Reset the time of the replaced solenoid to 0 on the Parts usage time management screen ...