Hitachi Command Control Interface (CCI) User and Reference Guide
215
(P,T#,L#) (TrueCopy) = port, TID, and LUN as described in the configuration definition
file. For further information on fibre-to-SCSI address conversion, see Appendix C.
(Port#,TID,LU-M) (ShadowImage) = port number, TID, LUN, and MU number as described
in the configuration definition file
Seq# = serial number of the RAID storage system
LDEV# = logical device number
P/S = volume attribute
Status = status of the paired volume
Fence (TrueCopy only) = fence level
% (TrueCopy only) = copy operation completion, or percent pair synchronization
Hitachi TrueCopy Async
Hitachi TrueCopy Sync
ShadowImage
Vol. COPY PAIR OTHER COPY PAIR OTHER COPY PAIR PVOL_PSUS
SVOL_COPY
OTHER
PVOL
CR SF BMP CR BMP
BMP CR CR
BMP
CR
SVOL - SF
BMP
- BMP
BMP
CR
CR
CR
CR
UR
Status
Volume COPY
PAIR
PSUS/SSUS
(PJNS/SJNS)
OTHER
PVOL CR
JF
JF
BMP
SVOL - JF
JF
BMP
CR: Shows the copy operation rate (identical rate of a pair).
BMP:
Shows the identical percentage of BITMAP both PVOL and SVOL.
SF:
Shows sidefile percentage of each CT group as sidefile 100% on cache of both PVOL and SVOL. Following is
an arithmetic expression using the High Water Mark (HWM) as 100% of a sidefile space:
HWM(%) = High water mark(%)/Sidefile space(30 to 70) * 100
JF
:
Shows the usage rate of the current journal data as 100% of the journal data space.
P-LDEV# = LDEV number of the partner volume of the pair
M
–
For P-VOL and “PSUS” state:
M=“W” shows that S-VOL is suspending with R/W enabled through the pairsplit.
M=“-” shows that S-VOL is suspending with Read only through the pairsplit.
–
For S-VOL and “SSUS”state:
M=“W” shows that S-VOL has been altered since entering SSUS state.
M=“-” shows that S-VOL has NOT been altered since entering SSUS state.
–
For “COPY/RCPY/PAIR/PSUE” state:
M=“N” shows that its volume are Read-disabled through the paircreate ‘-m noread’.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...