260
Chapter 4 Performing CCI Operations
Num
: Displays the number of LDEV configured the SnapShot pool.
LDEV#
: Displays the first number of LDEV configured the SnapShot pool.
H(%):
Displays the threshold rate being set to the SnapShot pool as High water mark.
‘Unknown’ will be shown as ‘-’.
# raidvchkscan -v pida 0
PID POLS U(%) AV_CAP(MB) TP_CAP(MB) W(%) H(%) Num LDEV# LCNT TL_CAP(MB)
001 POLN 10 45000000 50000000 50 80 2 265 33 65000000
002 POLF 95 10000 100000000 50 80 3 270 900 100000000
004 POLN 0 10000000 100000000 80 90 2 280 0 0
Figure 4.50 Raidvchkscan Command Example with -v pida Option
Output of the
raidqvchkscan
command with
-v pida
option:
PID
: Displays the HDP pool ID.
POLS
: Displays the status of the HDP pool:
–
POLN
= “Pool Normal”
–
POLF
= “Pool Full”
–
POLS
= “Pool Suspend”
–
POLE
= “Pool failure”. In this state, information for the pool cannot be displayed.
U(%)
: Displays the usage rate of the HDP pool.
AV_CAP(MB)
: Displays the available capacity for the HDP volumes mapped to this pool.
TP_CAP(MB)
: Displays the total capacity of the HDP pool.
W(%)
: Displays the threshold rate for “WARNING” set for this HDP pool.
H(%)
: Displays the threshold rate set for the HDP pool as high water mark.
Num
: Displays the number of LDEVs configured the HDP pool.
LDEV#
: Displays the first number of LDEV configured the HDP pool.
LCNT
: Displays the total number of HDP volumes mapped to this HDP pool.
TL_CAP(MB)
: Displays the total capacity of all HDP volumes mapped to this HDP pool.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...