Hitachi Command Control Interface (CCI) User and Reference Guide
173
4.3
Splitting and Deleting Pairs (Pairsplit)
The pairsplit command stops updates to the secondary volume of a pair and can either
maintain (status = PSUS) or delete (status = SMPL) the pairing status of the volumes (see
Table 4.3). The pairsplit command can be applied to a paired logical volume or a group of
paired volumes. The pairsplit command allows read access or read/write access to the
secondary volume, depending on the selected options. When the pairsplit command is
specified, acceptance of write requests to the primary volume depends on the fence level of
the pair (data, status, never, or async). Table 4.5 lists and describes the pairsplit command
parameters and returned values. Table 4.6 lists and describes the error codes for the
pairsplit command.
Pair
splitting
command
Server A
Server B
Primary
volume
(Secondary
volume)
Secondary
volume
(Primary
volume)
Paired logical volume
Figure 4.2
Pair Splitting
The primary volume’s server is automatically detected by the pairsplit command, so the
server does not need to be specified in the pairsplit command parameters. If the -S option
(simplex) is used, the volume pair is deleted, the volumes are returned to the simplex state,
and the primary and secondary volume status is lost. Paired volumes are split as soon as the
pairsplit command is issued. If you want to synchronize the volumes, the pairsplit command
must be issued after write I/Os to the paired volume have completed (see section 4.3.1 for
examples).
Note:
You can create and split ShadowImage pairs simultaneously using the
-split
option of
the paircreate command (refer to section 4.2).
Note on Quick Split:
If “$HORCC_SPLT=QUICK” environment variable is set (USP V/VM or
USP/NSC), the “pairsplit” and “paircreate -split” operations will be performed as Quick Split
regardless of the system option mode 122 setting on the SVP. The $HORCC_SPLT
environment variable is ignored by 9900V/9900.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...