Hitachi Command Control Interface (CCI) User and Reference Guide
79
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
HST1 horcm 1000 3000
HORCM_CMD
#dev_name
/dev/xxx [Note 1]
HORCM_DEV
#dev_group dev_name port# TargetID LU#
Oradb oradev1
CL1-A 1 1
Oradb oradev2
CL1-A 1 2
HORCM_INST
#dev_group ip_address service
Oradb HST2 horcm
Configuration file for HOSTA (/etc/horcm.conf)
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
HST2 horcm 1000 3000
HORCM_CMD
#dev_name
/dev/xxx [Note 1]
HORCM_DEV
#dev_group dev_name port# TargetID LU#
Oradb oradev1
CL1-D 2 1
Oradb oradev2
CL1-D 2 2
HORCM_INST
#dev_group ip_address service
Oradb HST1 horcm
Configuration file for HOSTB (/etc/horcm.conf)
LAN
Tx: Target ID
Lx: LUN
Note: Use of command device by user is not possible (command
device established from Remote Console PC or SVP).
Ip address:HST2
A B
CL1
Oradb
oradev1
oradev2
P-Vol
P-Vol
T1,L1
T1,L2
Command
device
T0,L1
C D
CL1
S-Vol
S-Vol
T2,L2
T2,L1
T0,L1
Hitachi RAID Storage System
HOSTA
HORCM
CONF.file
Ip address:HST1
C0
HOSTB
HORCM
CONF.file
C1
/dev/rdsk/c0t1d1
/dev/rdsk/c0t1d2
/dev/rdsk/c0t0d0
/dev/rdsk/c1t2d1
/dev/rdsk/c1t2d2
/dev/rdsk/c1t0d0
Fibre-channel
Fibre-channel
Fibre port
Fibre port
Figure 2.41 Hitachi TrueCopy Local Configuration Example
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...