130
Chapter 3 Preparing for CCI Operations
5.
Execute the HORCM installation command:
# /HORCM/horcminstall.sh
6.
Verify installation of the proper version using the
raidqry
command:
# raidqry -h
Model: RAID-Manager/HP-UX
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
Version Up
. To install a new version of the CCI software:
1.
Confirm that HORCM is not running. If it is running, shut it down:
One CCI instance:
# horcmshutdown.sh
Two CCI instances:
# horcmshutdown.sh 0 1
If Hitachi TrueCopy/ShadowImage commands are running in the interactive mode,
terminate the interactive mode and exit these commands using
-q
option.
2.
Insert the installation medium (e.g., CD-ROM) into the proper I/O device.
3.
Move to the directory containing the HORCM directory (e.g.,
# cd /
for root directory).
4.
Copy all files from the installation medium using the
cpio
command:
# cpio -idmu < /dev/XXXX
XXXX = I/O device
Preserve the directory structure (
d
flag) and file modification times (
m
flag) and copy
unconditionally (
u
flag). For floppy disks, load them sequentially, and repeat the
command. An input/output device name of floppy disk designates a surface partition of
the raw device file (unpartitioned raw device file).
5.
Execute the HORCM installation command:
# /HORCM/horcminstall.sh
6.
Verify installation of the proper version using the
raidqry
command:
# raidqry -h
Model: RAID-Manager/HP-UX
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...