Hitachi Command Control Interface (CCI) User and Reference Guide
189
Parameter Value
Returned values
When the -nowait option is specified:
Normal termination:
1:
The status is SMPL
2:
The status is COPY or RCPY
3:
The status is PAIR
4:
The status is PSUS
5:
The status is PSUE
When monitoring groups, 1/2/3/4/5 = normal termination for all pairs.
Abnormal termination:
other than 0 to 127, refer to the execution logs for error details.
When the -nowaits option is specified:
Normal termination:
1:
The status is SMPL
2:
The status is COPY or RCPY
3:
The status is PAIR
4:
The status is SSUS ((Note that SVOL_PSUS will be displayed as SSUS)
5:
The status is PSUE
When the -nowait and/or -nowaits option is not specified.
When the -nowait and or nowaits option is not specified:
Normal termination: 0. When monitoring groups, 0 = normal termination for all pairs.
Abnormal termination:
other than 0 to 127, refer to the execution logs for error details.
Table 4.10 Specific Error Codes for Pairevtwait
Category
Error Code
Error Message
Recommended Action
Value
Volume status
EX_ENQVOL
Unmatched volume status within the
group
Confirm status using the pairdisplay
command. Make sure all volumes in the
group have the same fence level and
volume attributes.
236
EX_INCSTG
Inconsistent status in group
Confirm pair status using pairdisplay.
229
EX_INVVOL
Invalid volume status
Confirm pair status using pairdisplay -l.
222
EX_EVOLCE
Pair Volume combination error
Confirm pair status using pairdisplay,
and change combination of volumes.
235
Unrecoverable
EX_EWSUSE
Pair suspended at WAIT state
Issue pairresync manually to the
identified failed paired volume to try to
recover it. If the trouble persists, call the
Hitachi Data Systems Support Center.
234
Timer
EX_EWSTOT
Timeout waiting for specified status
Increase timeout value using -t option.
233
Recoverable
EX_EWSLTO
Timeout waiting for specified status
on the local host
Confirm that CCI (HORCM) on the
remote host is running.
232
Note
:
Unrecoverable errors are fixed and will not be resolved, even after re-executing the
command. If the command failed, the detailed status will be logged in the CCI command log
($HORCC_LOG) (see Table A.2), even if the user script has no error handling.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...