Hitachi Command Control Interface (CCI) User and Reference Guide
231
# raidscan -p cl1-r
Port#, TargetID#, Lun# Num(LDEV#...) P/S,
Status, Fence, LDEV#, P-Seq# P-LDEV#
CL1-R,
15,
7
5(100,101...)
P-VOL
PAIR
NEVER
100,
5678
200
CL1-R,
15,
6
5(200,201...)
SMPL
----
----
----
----
# raidscan -p cl1-r -f
Port#, TargetID#,
Lun# Num(LDEV#...) P/S, Status,
Fence, LDEV#, Vol.Type
CL1-R,
15,
7
5(100,101...)
P-VOL
PAIR
NEVER
100,
OPEN-3
CL1-R,
15,
6
5(200,201...)
SMPL
----
----
----
OPEN-3
# raidscan -pd /dev/rdsk/c0t15/d7 -fg
Port#, TargetID#,
Lun# Num(LDEV#...) P/S, Status,
Fence, LDEV#, Group
CL1-R,
15,
7
5(100,101...)
P-VOL
PAIR
NEVER
100,
oradb
CL1-R,
15,
6
5(200,201...)
SMPL
----
----
----
oradb1
Specified device is LDEV# 0100.
Figure 4.27 Raidscan Command Examples for SCSI Ports
# raidscan -p cl1-r
PORT#/ALPA/C,
TID#, LU# Num(LDEV#...) P/S, Status, Fence, LDEV#, P-Seq# P-LDEV#
CL1-R/ ce/15,
15,
7
5(100,101..)
P-VOL PAIR
NEVER
100,
5678
200
CL1-R/ ce/15,
15,
6
5(200,201..)
SMPL ----
----
----
----
-----
# raidscan -p cl1-r -f
PORT#/ALPA/C, TID#,
LU#
Num(LDEV#...) P/S, Status,
Fence, LDEV#, Vol.Type
CL1-R/ ce/15,
15,
7
5(100,101..)
P-VOL PAIR
NEVER
100,
OPEN-3
CL1-R/ ce/15,
15,
6
5(200,201..)
SMPL ----
----
----
OPEN-3
Figure 4.28 Raidscan Command Examples for Fibre-Channel Ports
# ls /dev/rdsk/* | raidscan -find
DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID
/dev/rdsk/c0t0d4 0 S
CL1-M 0 4
31168 216 OPEN-3-CVS-CM
/dev/rdsk/c0t0d1 0 S
CL1-M 0 1
31168 117 OPEN-3-CVS
/dev/rdsk/c1t0d1 - -
CL1-M - -
31170 121 OPEN-3-CVS
Figure 4.29 Example of -find Option for Raidscan
Output of the
raidscan
command:
SCSI:
Port#, TargetID#, Lun#
= port ID, TID, and LU number (LUN)
Fibre:
Port#, ALPA/C, TID#, LU#
= port ID, arbitrated loop phys. address, TID, LUN. For
further information on fibre-to-SCSI address conversion, see Appendix C.
Note:
For ShadowImage,
raidscan
displays MU# for each LUN (e.g., LUN 7-0, 7-1, 7-2).
Num(LDEV#…)
= number of LDEVs and LDEV ID for the LUSE volume
P/S
= volume attribute
Status
= status of the paired volume
Fence
(TrueCopy only) = fence level
P-Seq#
= serial # of the storage system which contains the partner volume of the pair
P-LDEV#
= LDEV number of the partner volume of the pair
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...