Hitachi Command Control Interface (CCI) User and Reference Guide
319
Mount and Sync used Volume{GUID} for Windows 2008/2003/2000:
RAID Manager supports
the mount command option specified in the device object name, such as
“\Device\Harddiskvolume X”. Windows changes the device number for the device object
name after recovering from a failure of the PhysicalDrive. As a result, the mount command
specified in the device object name may be failed. Therefore, RAID Manager supports a
mount command option that specifies a Volume{GUID} as well as the device object name.
Mount
–
The mount command option will be able to specify a Volume{GUID} as well as the
device object name.
–
If a Volume{GUID} is specified, then it will be executed by converting a
Volume{GUID} to a device object name.
–
The user will be able to discover the Volume{GUID}s by using “inqraid $Volu -fv”
command option.
Examples
:
C:\HORCM\etc>inqraid -CLI $Vol -fv
DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID
R:Group
Æ
PRODUCT_ID
Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}\Vol3\Dsk0 CL2-D 62496 256 -
- - - OPEN-3-CVS-CM
[ Mount used DefineDosDevice() ]
Note:
This may forcibly dismount the mounted volume due to LOG-OFF of Windows
2008/2003/2000. For example:
C:\HORCM\etc>raidscan -x mount E: Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}
E: <+> HarddiskVolume3
[ Mount used Directory mount ]
Note:
This prevents the forcible removal of a volume due to LOG-OFF of Windows
2008/2003/2000. For example:
C:\HORCM\etc>raidscan -x mount E:\ Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}
E:\ <+> HarddiskVolume3
sync
–
The sync command option will also be able to specify a Volume{GUID} as well as the
device object name.
–
If a Volume{GUID} is specified, then it will be executed by converting a
Volume{GUID} to a device object name.
Example:
C:\HORCM\etc>raidscan -x sync Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}
[SYNC] Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...