Hitachi Command Control Interface (CCI) User and Reference Guide
167
Table 4.2
Relationship Between -I[inst#] Option and $HORCMINST and HORCC_MRCF
-I[inst#] option
$HORCMINST
Behavior
-I
Attaching w/o HORCMINST
-IX
Don’t care
Attaching to HORCMINST=X
HORCMINST=X
Attaching to HORCMINST=X
Unspecified
Unspecified
Attaching w/o HORCMINST
-IH, -IM or -ITC, -ISI option $HORCC_MRCF
Behavior
-IH or -ITC
Executing as HORC(TC) mode
-IM or -ISI
Don’t care
Executing as HOMRCF(SI) mode
HORCC_MRCF=1 Executing
as HOMRCF(SI) mode
Unspecified
Unspecified
Executing as HORC(TC) mode
X: this shows the Instance Number
4.1.2
Verifying $HORCC_MRCF,HORCMINST
RAID Manager provides a way to verify “$HORCC_MRCF” and “$HORCMINST” environment
variable so that a user can confirm RM instance number and Copy mode they are setting.
# pairdisplay -h
Model : RAID-Manager/Solaris
Ver&Rev: 01-22-03/02
Usage : pairdisplay [options] for HORC[5]
-h Help/Usage
-I[#] Set to the instance# of HORCM
-IH[#] Set to HORC mode [and the instance# of HORCM]
-IM[#] Set to HOMRCF mode [and the instance# of HORCM]
-z Set to the interactive mode
-zx Set to the interactive mode and HORCM monitoring
-q Quit(Return to main())
-g <group> Specify the group_name
Interactive mode
# pairdisplay -z
pairdisplay[HORC[5]]: -IM
pairdisplay[HOMRCF[5]]: -q
#
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...