Appendix C Fibre-to-SCSI Address Conversion
Conversion table for Windows.
The conversion table for Windows is based on conversion by
an Emulex driver. If the fibre-channel adapter is different (e.g., Qlogic, HP), the target ID
which is indicated by the
raidscan
command may be different from the target ID on the
Windows host.
Figure C.1 shows an example of using the
raidscan
command to display the TID and LUN of
Harddisk6 (HP driver).
Note:
You must start HORCM without the descriptions of HORCM_DEV
or HORCM_INST in the configuration definition file because of the unknown TIDs and LUNs.
C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4]
TId[ 3] Lun[ 5]
[HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S, Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/4, 29, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014
Figure C.2 Using Raidscan to Display TID and LUN for Fibre-Channel Devices
In this case, the target ID indicated by the
raidscan
command must be used in the
configuration definition file. This can be accomplished using either of the following two
methods:
Using default conversion table
. Use the TID# and LU# indicated by the
raidscan
command in the HORCM configuration definition file (TID=29 LUN=5 in Figure C.2).
Changing default conversion table
. Change the default conversion table using the
HORCMFCTBL environmental variable (see Figure C.3) (TID=3 LUN=5 in Figure C.3).
C:\> set HORCMFCTBL=X
Å
'X' is fibre conversion table number.
C:\> horcmstart ...
Å
Start of HORCM.
:
:
Result of "set HORCMFCTBL=X" command:
C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4]
TId[ 3] Lun[ 5]
[HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S,Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/0, 3, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014
Figure C.3 Using HORCMFCTBL to Change the Default Fibre Conversion Table
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...