54
Chapter 2 Overview of CCI Operations
dev_name
for UNIX
In UNIX SAN environment, there are situations when the device file name will be changed, a
failover operation in UNIX SAN environment or every reboot under Linux when the SAN is
reconfigured. The CCI user needs to find NEW "Device Special File" and change HORCM_CMD
described in the CCI configuration file. Thus, CCI supports the following naming format
specifying Serial#/LDEV#/Port#:
HINT
as notation of the command device
for UNIX
:
\\.\CMD-Ser#-ldev#-Port#:
HINT
HORCM_CMD
#dev_name dev_name dev_name
\\.\CMD-30095-250-CL1-A-1:
/dev/rdsk/
If these names are specified, HORCM finds “\\.\CMD-Serial#-Ldev#-Port#” from the device
files specified by
HINT
at HORCM start-up. HINT must be specified “directory terminated
with ‘/’ on the device file name” or “directory including device file name pattern” as
below, for example:
/dev/rdsk/
Æ
this finds a specified CMD from /dev/rdsk/*
/dev/rdsk/c10
Æ
this finds a specified CMD from /dev/rdsk/c10*
/dev/rhdisk
Æ
this finds a specified CMD from /dev/rhdisk*
The device files discovered during HINT are filtered with the following pattern:
HP-UX: /dev/rdsk/*
or
/dev/rdisk/disk*
Solaris: /dev/rdsk/*s2, AIX: /dev/rhdisk*
Linux : /dev/sd...., zLinux : /dev/sd....
MPE/iX: /dev/...
Tru64: /dev/rrz*c or /dev/rdisk/dsk*c or /dev/cport/scp*
DYNIX: /dev/rdsk/sd*
IRIX64: /dev/rdsk/*vol or /dev/rdsk/node_wwn/*vol/*
If a HINT is already specified, “
:HINT
” can be omitted for next command devices, and then a
command device will be found from the cached Inquiry information of HORCM for saving
unnecessary device scanning.
HORCM_CMD
#dev_name dev_name dev_name
\\.\CMD-30095-250-CL1:
/dev/rdsk/
\\.\CMD-30095-250-CL2
Example for minimum specification. Specifies to use any command device for Serial#30095:
\\.\CMD-30095:/dev/rdsk/
Example for under Multi Path Driver. Specifies to use any port as the command device for
Serial#30095, LDEV#250:
\\.\CMD-30095-250:/dev/rdsk/
Example for full specification. Specifies the command device for Serial#30095, LDEV#250
connected to Port CL1-A, Host group#1:
\\.\CMD-30095-250-CL1-A-1:/dev/rdsk/
Other examples:
\\.\CMD-30095-250-CL1:/dev/rdsk/ \\.\CMD-30095-250-CL2
\\.\CMD-30095:/dev/rdsk/c1 \\.\CMD-30095:/dev/rdsk/c2
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...