254
Chapter 4 Performing CCI Operations
# raidvchkscan -v pool -p CL2-d-0
PORT# /ALPA/C TID# LU# Seq# Num LDEV# Bsize Available Capacity
CL2-D-0 /e4/ 0 2 0 62500 1 160 2048 100000 1000000000
CL2-D-0 /e4/ 0 2 1 62500 1 161 2048 100000 1000000000
Figure 4.44 Raidvchkscan Command Example with -v pool Option
Output of the
raidqvchkscan
command with
-v pool
option:
Bsize
: This displays the data block size of the pool, in units of block (512 bytes).
Available(Bsize)
: This displays the available capacity for the volume data on the
SnapShot pool in units of Bsize.
Capacity(Bsize)
: This displays the total capacity in the SnapShot pool in units of Bsize.
# raidvchkscan -v aou -p CL2-d-0
PORT# /ALPA/C TID# LU# Seq# Num LDEV# Used(MB) LU_CAP(MB) U(%) T(%) PID
CL2-D-0 /e4/ 0 2 0 62500 1 160 20050 1100000 1 60 1
CL2-D-0 /e4/ 0 2 1 62500 1 161 200500 1100000 18 60 2
Figure 4.45 Raidvchkscan Command Example with -v aou Option
Output of the
raidvchkscan
command with
-v aou
option:
Used(MB)
: Displays the usage size the allocated block on this LUN.
Range: 0
≤
Used (MB) < LU_CAP(MB) + 42MB
LU_CAP(MB)
: Displays the LUN capacity responded to the “Readcapacity” command as
SCSI interface.
U(%)
: Displays the usage rate of the allocated block on the AOU pool containing this LU.
T(%)
: Displays the threshold rate being set to the AOU pool as high water mark.
PID
: Displays the AOU pool ID assigned to this AOU volume.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...