Hitachi Command Control Interface (CCI) User and Reference Guide
343
5.3
Error Reporting
Table 5.2 lists and describes the HORCM system log messages and provides guidelines for
resolving the error conditions. Table 5.3 lists and describes the command error messages and
their return values and also provides guidelines for resolving the error conditions. Table 5.4
and Table 5.5 list the generic error codes. Table 5.6 lists the specific error codes.
Table 5.2
System Log Messages
Message ID
Condition
Cause
Recommended Action
HORCM_001 The HORCM log file cannot be
opened.
The file cannot be created in the
HORCM directory.
Create space on the disk on which the root
directory resides.
HORCM_002 The HORCM trace file cannot be
opened.
The file cannot be created in the
HORCM directory.
Create space on the disk on which the root
directory resides.
HORCM_003 The HORCM daemon process
cannot create a child process due to
an error.
HORCM daemon attempted to
create more processes than the
maximum allowable number.
Terminate unnecessary programs or daemon
processes running simultaneously.
HORCM_004 HORCM assertion failed, resulting in
a fatal internal error in the HORCM.
An internal error which could not be
identified by the HORCM occurred.
Restart the system, and call the Hitachi Data
Systems support center.
HORCM_005 The CCI software failed to create
the end point for remote
communication.
HORCM failed to create a socket, or
an error exists in the HORCM
configuration file ($HORCM_CONF).
Refer to the HORCM startup log to identify
the cause of the error.
HORCM_006 HORCM memory allocation failed.
HORCM memory could not be
secured.
Increase the system virtual memory, or close
any unnecessary programs.
HORCM_007 An error exists in the HORCM setup
file.
An error exists in the HORCM setup
file.
Refer to the startup log and reset the
parameters.
HORCM_008 HORCM configuration file
parameters could not be read.
An error exists in the format or
parameters of the HORCM
configuration file ($HORCM_CONF).
Refer to the HORCM startup log to identify
the cause of the error.
HORCM_009 HORC/HOMRCF connection to the
CCI software failed.
System devices are improperly
connected, or an error exists in the
HORCM configuration file.
Refer to the HORCM startup log to identify
the cause of the error.
HORCM_101 HORC/HOMRCF
and
the
CCI
software communication fails.
A system I/O error occurred or an
error exists in the HORCM
configuration file ($HORCM_CONF).
Refer to the HORCM startup log to identify
the cause of the error.
HORCM_102 The volume is suspended.
The pair status was suspended due
to code XXXX.
Call the Hitachi Data Systems support center.
HORCM_103 Detected a validation check error on
this volume (xxxx unit#x,ldev#x) :
CfEC=n, MNEC=n, SCEC=n,
BNEC=n
A validation error occurs on the
database volume, or validation
parameters for this volume are
illegal.
Please confirm the following items, and use
raidvchkdsp -v <op> command for verifying
the validation parameters.
(1) Check if the block size (-vs <size>) is an
appropriate size.
(2) Check if the type for checking (-vt <type>)
is an appropriate type.
(3) Check if the data validations are disabled
for LVM configuration changes.
(4) Check if the data validations are not used
based on file system.
(5) Check if the redo log and data file are
separated among the volumes.
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...