348 Chapter
5
Troubleshooting
The codes in Table 5.4 indicate generic errors returned by the following commands:
horctakeover
,
paircurchk
,
paircreate
,
pairsplit
,
pairresync
,
pairevtwait
,
pairvolchk
,
pairsyncwait
,
pairdisplay
. Unrecoverable error should be done without re-execute by
handling of an error code. Recoverable error can re-execute by handling of an error code.
Table 5.4
Generic Error Codes (horctakeover, paircurchk, paircreate, pairsplit, pairresync, pairevtwait,
pairvolchk, pairsyncwait, pairdisplay)
Category
Error Code
Error Message
Value
Syntax for Argument
EX_REQARG
Required Arg list
254
EX_INVARG
Invalid argument
253
EX_INVNAM
Invalid name of option
249
EX_UNWOPT
Unknown
option
252
EX_UNWCOD
Unknown
function
code
238
EX_UNWCMD
Unknown
command
230
EX_ERANGE
Result too large
244
EX_ENAMLG
File name too long
243
Unrecoverable
EX_INVRCD
Invalid return code
226
Configuration
EX_ENOGRP
No such group
239
EX_ENOENT
No such device or group
247
EX_ENODEV
No such device
246
EX_ENLDEV
No such LDEV within the RAID
227
EX_ENOUNT
No such RAID unit
219
EX_INVMUN
Invalid mu# with HORC or HOMRCF
220
EX_ENQSER
Unmatched Serial# vs RAID unitID
218
EX_EXTCTG
Extended CTgroup across RAIDs
216
EX_ENQCTG
Unmatched CTGID within the group
214
EX_ENPERM
Permission denied with the LDEV
213
EX_ERPERM
Permission denied with the RAID
211
Unrecoverable
EX_ESPERM
Permission denied with the SLPR
207
Command I/O to RAID
EX_CMDRJE
An order to the control/command was rejected
221
EX_CMDIOE
Control command I/O error, or rejected
237
EX_OPTINV
A specified option is invalid
248
EX_INVMOD
Invalid RAID command mode
241
Recoverable
EX_INVCMD
Invalid RAID command
240
Communication for HORCM
EX_ATTHOR
Cannot attached to HORC manager
251
EX_ATTDBG
Cannot attached to a Debug layer
250
EX_COMERR
Cannot communicate with HORC manager
255
Recoverable
EX_ENORMT
No remote host alive for remote commands, or Remote CCI might
be blocked (sleeping) on an existing I/O.
242
Resource
Unrecoverable
EX_ENOMEM
Not enough core
245
Содержание TAGMASTORE MK-90RD011-25
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 18: ...xviii Contents ...
Страница 180: ...162 Chapter 3 Preparing for CCI Operations ...
Страница 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Страница 370: ...352 Chapter 5 Troubleshooting ...
Страница 388: ...370 Acronyms and Abbreviations ...