95
10.2
REMOTE CONTROL CONNECTION ON THE GROUND CONNECTOR
To connect remote control on the ground, using its ground cable, could be
useful in case of demonstrations or in case of particular diagnoses.
The remote control ground cable is under the slot on the left side of the electric
components compartment, installed on the machine rear side of the machine.
Connecting the remote control on the ground it’s possible to move both ground
part and aerial part, for aerial part of course remote control must not be into
its basket support
and it’s
not necessary to have the pedal pressed even in case
of it is activated.
It’s forbidden to use the remote control connected on the ground while
someone is in the basket, except for emergency reasons.
At the ground cable is connected the CONNECTOR JUMPER, necessary to close
the STOP lines on basket connector.
If the remote control is connected to the basket connector but the control
position selector switch is wrongly turned left to select the remote control
ground position, the display will show the here below icon.
The procedure to connect the remote control on the ground is detailed here
below.
1.
Make sure that the main key on ground control box is turned OFF and
that remote control display is OFF too
2.
Disconnect the remote control from its basket cable connector and fit the
CONNECTOR JUMPER on the same cable connector
CONNECTOR
JUMPER
REMOTE
CONTROL
GROUND
WRONG REMOTE CONTROL
POSITION SELECTED
Содержание LightLift 15.70 3S
Страница 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Страница 12: ...12 ...
Страница 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Страница 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Страница 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Страница 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Страница 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Страница 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Страница 108: ...108 CELLS PACK WITHOUT COVER ...