123
EXAMPLE OF MACHINE WITH A COIL CONNECTION ERROR
In case of the coil of the ON-OFF valve for third boom lifting is disconnected
from its cabling or in case of its cable is ripped, when pushing one of the black
joysticks, the aerial part movement will not be carried out and the icon FAIL
INPUT OUTPUT will be displayed.
On this case on the CODE MENU at the DEVICE 37 the ERROR 2 (Open load
error) or ERROR 5 (Short circuit to battery plus), will be displayed as “ACTIVE
YES”, while some other DEVICE between the 36 and the 56 will be displayed
with ERROR 7 (Safety deactivation).
COIL CONNECTION ERROR EXAMPLE
DEVICE CODE
ERROR CODE
ACTIVE
12
9
YES
36
7
YES
1-2 booms lifting valve coil
37
5
YES
3 boom lifting valve coil
38
7
YES
1-2 booms lowering valve coil
39
7
YES
3 boom lowering valve coil
40
7
YES
Telescope extraction valve coil
41
7
YES
Telescope retraction valve coil
42
7
YES
Jib opening valve coil
43
7
YES
Jib closing valve coil
44
7
YES
Basket levelling up valve coil
45
7
YES
Basket levelling down valve coil
46
7
YES
Turntable right rotation valve coil
47
7
YES
Turntable left rotation valve coil
48
7
YES
Basket right rotation valve coil
49
7
YES
Basket left rotation valve coil
64
2
YES
65
9
NO
66
9
NO
67
4
YES
73
2
NO
89
12
YES
133
1
YES
145
2
YES
154
8
NO
155
8
NO
Содержание LightLift 15.70 3S
Страница 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Страница 12: ...12 ...
Страница 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Страница 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Страница 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Страница 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Страница 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Страница 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Страница 108: ...108 CELLS PACK WITHOUT COVER ...