124
EXAMPLE OF MACHINE WITH A COIL CONNECTION ERROR AFTER KEY RESET
From the software release 2.0, resetting the machine by the main key the aerial
part movements will be re-activated, except for the third boom lowering that
will be re-activated only after its coil anomaly is restored.
COIL CONNECTION ERROR AFTER KEY RESET
EXAMPLE
DEVICE CODE
ERROR CODE
ACTIVE
12
9
YES
37
2
YES
3 boom lifting valve coil
64
2
YES
65
9
NO
66
9
NO
67
4
YES
73
2
NO
89
12
YES
133
1
YES
145
2
YES
154
8
NO
155
8
NO