135
ST34 CLOSED
ON
Pressure switch of outriggers n.3 and n.4 closes the contact
–
the
outriggers are at end run and the max pressure valve is opened
OFF
Pressure switch contact of outriggers n.3 and n.4 is opened
–
the
outriggers are open, partially open or already closed
TEMP. ALRMA
Option
ON
Temperature external probe reached the maximum value, the
temperature probe is closed
OFF
Temperature external probe
hasn’t reached the maximum value,
the
temperature probe is open
GENERATOR
ON
Engine is running
OFF
Engine is not running
EMRG. COMM
ON
The control position selector for aerial part operation from the ground
is activated (emergency condition)
OFF
The control position selector for aerial part operation is released
(normal working condition)
START M.TE
ON
The ground button for engine start is pressed
OFF
The ground button for engine start is released
START M.EL
ON
The ground button for electric motor start is pressed
OFF
The ground button for electric motor start is released
GND/BASKET
ON
The control position selector is positioned on “basket”
OFF
The control position selector is positioned on “ground”
Содержание LightLift 15.70 3S
Страница 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Страница 12: ...12 ...
Страница 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Страница 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Страница 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Страница 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Страница 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Страница 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Страница 108: ...108 CELLS PACK WITHOUT COVER ...