38
7.2.4
EMERGENCY DESCENT FROM THE GROUND WITH HAND PUMP
EMERGENCY POTENTIAL SITUATIONS:
Engine and/or electric motor not working
Electrical system out of order
The only purpose of the emergency descent from the ground with hand pump
is a machine breakdown. Any other use is forbidden.
To carry out the movement required hydraulic oil has to be manually pumped
while using the ground controls.
Hand pump is not designed for lifting booms, i
t’s forbidden to carry out different
operations than the ones specified by the present procedure, in particular are
forbidden operations such as telescope opening, booms lifting, outriggers
movements while machine is not closed and aligned or with person in the
basket, in general any operation that may compromise the machine stability.
To carry out emergency descent from the ground with hand pump the here
below steps have to strictly followed.
a)
Turn OFF the main key
b)
Shift the deviator on the manual pump into the position for aerial part
movement (rightward) as indicated by the hand pump sticker and place
the hand pump lever, that is under the aerial part valveblock carter.
HAND PUMP
DEVIATOR
HAND PUMP
LEVER
Содержание LightLift 15.70 3S
Страница 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Страница 12: ...12 ...
Страница 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Страница 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Страница 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Страница 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Страница 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Страница 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Страница 108: ...108 CELLS PACK WITHOUT COVER ...