115
CONNECTOR ON
REMOTE
CONTROL THE
GROUND CABLE
Here follows the calibration procedure:
1
CONNECT THE REMOTE CONTROL AT ITS
GROUND CABLE AND SELECT THE CONTROL
POSITION ACCORDINGLY BY THE CONTROL
POSITION SELECTOR SWITCH
2
Turn ON the main key and select the correct machine model with button n.1
(VERSION), the display shows the machine model selected.
If it appears “MOD.CODE FAIL!”, it means
that the machine model selected
is not correct, even if that alarm does not appear on the display the machine
model selected need to be check.
Here below the example shows on the image A the case of machine model
selected is wrong, and on image B the case of machine model selected is
the right one (for a LL15.70)
3
In case of the engine model selected is not correct with button n.7 (MOTOR)
select the correct one (for instance “D.RPM” is the diesel Hatz 1B40 and
“G.13L” is the gasoline
Honda iGX390)
B
MACHINE MODEL
SELECTED IS OK
A
MACHINE MODEL
SELECTED IS WRONG