7 Cleaning and servicing the heating system – Requirements
91
C
LEANING
THE
CLEANING
SHAFT
AND
TURBULATORS
1.
Switch the heating system off.
✎
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.3 Switching off the heating system”.
2.
Allow the fire to burn out and cool down.
3.
Remove the top cover (1 or 5) on the feed side.
4.
Remove the top cover (2) or the rear and front top panels (3+6).
5.
Remove the cover (4) of the heat exchanger cleaner.
6.
In manual mode move the turbulators to the lowest position.
✎
See the “HDG Control” operating manual, chapter “6 Parameter
HDG Compact 25 - 80” section “6.2 Boiler” paragraph “Test”.
7.
Turn the main switch off.
Important!
✎
Observe the “Generally applicable safety instructions” in this sec-
tion.
Warning!
Danger of injury
The cleaning shaft lid is very heavy and can fall shut. Hands and
arms could thereby be crushed.
Take care not to bump into the opened cleaning shaft lid and cause
it to fall shut.
Figure 7/11 - Removing hoods
4
3
6
2
1
HDG Compact 25/35
HDG Compact 45/50/65/80
5
Содержание Compact 25