7-13
SECTION 7 –
DETASSELING SYSTEMS
Set the Lift Down Offset
(System must be in parameter mode
before proceeding)
•
Press the LIFT 1 UP Switch
seven (7)
times
to display the current setting of the
Down Offset for the first three lifts.
•
The Down Offset can be adjusted for a
value from -19 to +20.
NOTE: The more positive the number, the
faster the lift will move. Typically, the
offset is initially adjusted at a slower
speed by setting the Lift Down
Speed to 03.
•
Exit parameter mode and check the
speed of each lift by moving it manually
with the Up/Down Switches.
•
Correct the fastest and slowest lifts to
match the average speed by changing
the offset value with the Up/Down
Switches for that lift while in the Down
Offset parameter.
•
When finished setting the offset values,
return the speed setting back to approxi-
mately 05.
•
With all lifts at their highest points, select
AUTO so all lifts move down together.
Correct the values for any lifts that are
not close to the speed of the others.
NOTE: Values can be saved by pressing the
LIFT 1 DOWN Switch to exit the
screen and save the new parameter
setting.
Once you have set the operating
parameters, you may adjust the Response
Parameters. These parameters are used to
adjust the response of the controller and
seldom need changing. The parameter
values are stored in flash memory and will be
retained even when no battery power is
present.
The programmable control panel is
factory preset with the following parameter
defaults:
• Response Parameter (R2)
• Top Parameter (T3)
• Bottom Parameter (B1)
These parameters will always be
displayed until the control panel is
reprogrammed. Once reprogrammed, the
new values for the parameters will be
displayed on the control panel.
NOTICE
Once parameters have been set,
minimal adjustment is required.