SECTION 5 –
HYDRAULIC SYSTEMS
5-3
Dump Valve
The Dump Valve (located beneath the
operator’s seat) is the main valve, which
controls the amount of pressure going to the
lift valve.
NOTE: The Dump Valve is factory pre-set to
2200 psi (151.7 bar).
NOTE: To check Dump Valve psi/bar, install
a 3000 psi (206.8 bar) pressure
gauge on the Dump Valve Inlet. If
additional adjustment is required,
contact your John Deere dealer for
assistance.
Detasseling Heads
The hydraulic motors on the detasseling
heads are controlled by the Master
Detasseler Switch and are individually turned
on/off using the Detasseling Head Motor
Control Switches (located on the side
console).
Motor Control Valves
•
To open the solenoid on the Motor Con-
trol Valve(s) (which activate the motors),
press the corresponding Detasseling
Head Motor Control Switch(es) (located
on the side console) in the ON (Up) posi-
tion.
•
Press Detasseling Head Motor Control
Switch(es) in the OFF (Down) position to
turn motors off.
NOTE: Activate hydraulic motors while
engine speed is at idle, then increase
engine RPM to operating speed.
Electro-Hydraulic Valves
(Located on the front of tool bar)
-Typical View
Dump Valve
(Located beneath operator’s seat)
-Typical View
• Dump
Valve Inlet
• Detasseling Head
Motor Control
Switches
• Master Detasseler
Switch
Master Detasseler and Detasseling
Head Motor Control Switches
(Located on the side console)
-Typical View