SECTION 7 –
DETASSELING SYSTEMS
7-12
•
Exit parameter mode and check the
speed of each lift by moving it manually
with the Up/Down Switches.
•
Correct the fastest and slowest lifts to
match the average speed by changing
the offset value with the Up/Down
Switches for that lift while in the Lift Up
Offset parameter mode.
•
When finished setting the offset values,
return the speed setting back to approxi-
mately 05.
•
With all the lifts at their lowest points,
select AUTO.
•
Press the All Up Switch (located on the
Hydrostatic Drive Control Handle) so the
lifts all move up at the same time. Cor-
rect the values for any lifts that are not
close to the speed of the others.
NOTE: Values can be saved by pressing the
LIFT 1 DOWN Switch to exit the
screen and save the new parameter
setting.
Set the Lift Down Speeds
(System must be in parameter mode
before proceeding)
•
Press the LIFT 1 UP Switch
six (6)
times
and the display will show the cur-
rent setting of the Down Speed for an
auto, manual, and all-resume move with
a value of 01 to 10.
•
With the value set to 03, the lifts will
move a little slower. This setting of 03 is
useful when adjusting the offset of the
values for getting all the lifts the same
speed.
Typically, these values are set to 05 for a
fairly fast speed. The values can be
changed by pressing the Up/Down
Switches under the AUTO, MAN, or ALL.
NOTE: Values can be saved by pressing the
LIFT 1 DOWN Switch to exit the
screen and save the new parameter
setting.
NOTICE
To get all the lift speeds even, you may
need to lower the speed below 05. This
will ensure that flow is being controlled
by the value rather than restricted by the
.042” (.1 cm) orifice. After adjusting the
offset parameters for even up speeds,
the up speed value can be increased
back to 05.