7-11
SECTION 7 –
DETASSELING SYSTEMS
•
The “D” value indicates how many sec-
onds that the lifts will travel up after the
All Up Switch (located on the Hydrostatic
Drive Control Handle) is pressed
momentarily. This time can be changed
by pressing the LIFT 4 UP Switch.
NOTE: The time is factory preset to 0, but
can be set to a value of 25 while
adjusting the machine valves.
•
Pressing the LIFT 4 UP Switch will add
five (5) seconds to the value each time
until “D25”, then will return to “D00”.
When the value is set to D00, the up
motion stops as soon as the All Up
Switch is released.
If the value is set to anything greater
than D00, the All Up Switch will only
need to be pressed momentarily and the
lifts will continue the up move until the
parameter has been reached.
•
The “V” value indicates whether or not
the valve automatic compensation is
performed. Press the LIFT 6 UP Switch
to change this value.
NOTE: This value is typically left at “V1”.
Set the Lift Up Speeds
(System must be in parameter mode
before proceeding)
•
Press the LIFT 1 UP Switch
three (3)
times
and the display will show the cur-
rent setting of the Up Speed for an auto,
manual, and all-up move with a value
from 01 to 10.
•
With the value set to 01 in “MAN” or to
03 in “AUTO” and “ALL”, the lifts will
move slow enough to see if any are mov-
ing slower than the rest. These settings
are useful when adjusting the offset of
the values to get all the lifts to move at
the same speed. Typically, these values
are set to 05 for a fairly fast speed. The
values can be changed by pressing the
Up/Down Switches under AUTO, MAN,
or ALL.
NOTE: Values can be saved by pressing the
LIFT 1 DOWN Switch to exit the
screen and save the new parameter
setting.
Set the Lift Up Offset
(System must be in parameter mode
before proceeding)
•
Press the LIFT 1 UP Switch
four (4)
times
and the display will show the cur-
rent setting of the Up Offset for the first
three lifts. Pressing NEXT again will
show the offset setting for the last three
lifts.
The Up Offset for each valve can be set
from -19 to +20, as needed to get the lift
speed to match the speed of the other
lifts.
NOTE: The more positive the number, the
faster the lift will move. Typically, the
offset is initially adjusted at a very
slow speed by setting the Lift Up
Speed to either 01 or 03.
Содержание 204SP
Страница 2: ...5 DASH AUTO...
Страница 127: ......